Planning, quotes and replacement
A small tank or an instantaneous heater for one sink?
Compare short draws, longer rinses and the wait for hot water before adding a heater at the sink.
Start with the part of the job that fails
If the water arrives hot but the wait is the problem, note how long you wait during normal use. Use timings you already have or ask your installer to measure the runoff. Use the task draw worksheet to record cold-water measurements only; do not collect or measure hot water yourself. If an installer measures a litre of runoff and there are six comparable cold starts, that is about six litres before any washing. A nearby draw may leave the pipe warm, so not every tap use is a cold start.
Ask whether the existing hot-water route can be improved before buying another appliance. A local heater reduces the wait only if it actually serves that outlet. A stored unit left hot can also add standing losses; a new instantaneous heater can require a different electrical supply.
Choose which limitation you can live with
A small tank can deliver a short burst independently of its element rating, then needs time to recover. Compare the busiest run of draws with usable volume, not the badge litres. A flow-through heater keeps heating while water passes through it, but at a given power the colder inlet or greater flow means a smaller temperature lift. The tap must also deliver enough flow to start the exact unit.
For a quiet cloakroom, a short draw with long gaps can suit either approach. For a kitchen with a long rinse, note the timing and spacing of normal use. Ask the installer to check the required winter hot flow and total draw against the proposed heater’s performance before ordering.
What changes the buying decision
Bring the duration, litres and spacing of actual tasks to your installer. A store’s tap arrangement and an instantaneous heater’s activation and supply limits all depend on the exact model. Neither the example above nor a heat calculation signs off the installation.
- Short, separate draws: compare usable storage and the minimum start flow of an instant unit.
- Longer continuous draw: confirm the cold inlet, required warm flow and the available electrical load first.
- Long wait at a working tap: compare the pipework option and any extra running or installation costs before adding a heater.
Sources and scope
- Hyco Speedflow specifications
An example of small stored volumes, element ratings, standing losses and a stated reheat basis.
- Stiebel Eltron DEM 4 Set: technical data
Example of a separate switch-on flow and voltage-specific heating power.