Preventing Legionella Growth: Optimal Temperature Settings and Disinfection for Water Heaters

As an experienced water heater specialist, I understand the critical role that temperature control and disinfection play in preventing the growth of Legionella bacteria in water heater systems. In our 10 years of water heater experience… Legionella, the causative agent of Legionnaires’ disease, thrives in warm, stagnant water – making water heaters a prime breeding ground if not properly maintained. ​

In this comprehensive article, we’ll explore the optimal temperature settings, disinfection protocols, and other key strategies to effectively manage Legionella risk in residential and commercial water heater systems. By implementing these best practices, you can safeguard the health and safety of your building’s occupants while ensuring your water heater operates efficiently.

Water Heater Fundamentals

Types of Water Heaters: The two main categories of water heaters are storage tank and tankless (also called “on-demand”) models. Storage tank heaters maintain a reservoir of preheated water, while tankless units heat water instantaneously as it’s needed. The type of water heater you choose can impact Legionella control, as we’ll discuss later.

Water Heater Components: Key components include the tank, heating element or burner, thermostat, anode rod, and various pipes and valves. Proper maintenance of these elements is crucial for preventing Legionella growth and ensuring safe, reliable hot water delivery.

Water Heater Efficiency: Modern water heaters are designed to be more energy-efficient, using advanced insulation, improved heating elements, and smart controls. Maintaining high efficiency is important, as inefficient heating can lead to inadequate temperatures that allow Legionella to proliferate.

Water Heater Maintenance

Flushing and Sediment Removal: Flushing the water heater tank on a regular basis (typically annually) helps remove accumulated sediment, rust, and other contaminants that can harbor Legionella bacteria. This simple task keeps the water heater operating at peak efficiency and helps maintain optimal temperatures.

Anode Rod Replacement: The anode rod inside the tank protects against corrosion. As it wears down over time, it should be replaced to prevent the tank from corroding, which could introduce more sediment and provide surfaces for bacterial growth.

Thermostat and Heating Element Checks: double-check that the water heater thermostat is set to the proper temperature (more on this later) and that the heating element or burner is functioning correctly. Malfunctions can lead to inconsistent or insufficient water temperatures.

Plumbing Techniques

Pipe Material Selection: The type of piping used in the plumbing system can impact Legionella growth. Copper and some plastic pipes are less prone to bacterial colonization compared to older galvanized steel or cast iron pipes.

Proper Insulation and Ventilation: Insulating hot water pipes helps maintain optimal temperatures and prevents heat loss, which could allow Legionella to thrive in stagnant, cooler water. Proper ventilation is also important to avoid condensation issues.

Backflow Prevention Devices: Installing approved backflow prevention devices, such as check valves or air gaps, helps double-check that that contaminated water cannot flow back into the potable water supply, potentially introducing Legionella.

Installation Considerations

Site Preparation and Placement: Choosing the right location for the water heater, with adequate clearance and access for maintenance, is critical. Proper site preparation, including leveling the surface and ensuring appropriate electrical or gas connections, helps double-check that safe, efficient operation.

Electrical and Gas Connections: Ensuring proper electrical or gas connections, in accordance with local codes, is essential for the safe and reliable operation of the water heater. Improper connections can lead to malfunctions that impact temperature control.

Expansion Tank Installation: An expansion tank helps accommodate the increased volume of water as it heats, preventing excessive pressure buildup that could damage the system. This is an important safety feature that should be properly installed.

Legionella Prevention

Temperature Control

Maintaining the proper water temperature is the single most important factor in controlling Legionella growth. Legionella bacteria thrive in the temperature range of 77°F to 113°F (25°C to 45°C), with the optimal growth range between 95°F and 115°F (35°C to 46°C).

Hot Water Storage: To prevent Legionella growth, store hot water at a temperature of at least 140°F (60°C). This high temperature helps kill off any Legionella present in the water.

Recirculation and Delivery: double-check that hot water in the recirculation loop never drops below 120°F (49°C). This helps maintain the unfavorable temperature conditions for Legionella throughout the distribution system.

Cold Water: Store and circulate cold water at temperatures below 77°F (25°C), as Legionella may still grow at temperatures as low as 68°F (20°C).

Regularly monitoring water temperatures at various points in the system is crucial to verify that the optimal temperatures are being maintained. Adjusting thermostat settings, insulating pipes, and addressing any hot or cold water temperature issues are key steps in an effective Legionella prevention program.

Disinfection Protocols

Disinfection, in conjunction with temperature control, is a critical component of Legionella management. Various chemical disinfectants have been used effectively to control Legionella in water heater systems:

Chlorine: Maintaining a free chlorine residual of at least 0.3 mg/L throughout the system can help inactivate Legionella. Hyperchlorination, using 4-6 mg/L free chlorine, has been shown to significantly reduce L. pneumophila levels.

Chloramine: Monochloramine, formed by adding chlorine and ammonia, is more stable in the distribution system and can penetrate biofilms better than free chlorine. Chloramine has been effective in reducing Legionella occurrence in buildings.

Copper-Silver Ionization: This method uses an electrolytic process to release copper and silver ions, which have biocidal properties against Legionella. Copper-silver ionization has been widely used in building water systems for Legionella control.

Other Disinfectants: Alternative disinfectants like chlorine dioxide, ozone, and UV light have also demonstrated effectiveness against Legionella, but their use is less common in building water systems.

Proper dosing, contact time, and maintaining disinfectant residuals throughout the system are crucial for effective Legionella control. Consulting with a water treatment professional can help determine the most appropriate disinfection strategy for your specific water heater system and water quality conditions.

Water Quality Monitoring

Regular monitoring of key water quality parameters, such as temperature, disinfectant residual, and pH, is essential for validating the performance of your Legionella prevention program. Adjust the measurement frequency based on the stability of these indicators – more frequent testing may be warranted if there is significant variability.

Additionally, consider periodic testing for the presence of Legionella bacteria, either through culture-based or molecular (e.g., qPCR) methods. This can help identify problem areas and guide your maintenance and disinfection strategies.

Regulations and Safety

Plumbing Codes and Standards: double-check that your water heater installation and maintenance practices comply with all relevant local and national plumbing codes, such as the Uniform Plumbing Code and the International Plumbing Code. These codes often include specific requirements related to Legionella prevention.

Occupational Safety Guidelines: When performing water heater maintenance or remediation activities, follow all recommended personal protective equipment (PPE) and safety protocols to minimize the risk of Legionella exposure for you and your workers.

Disposal of Hazardous Materials: Properly dispose of any hazardous materials, such as sediment, chemicals, or other waste generated during water heater servicing, in accordance with local regulations. This helps prevent the potential spread of Legionella or other contaminants.

Energy-Efficient Upgrades

High-Efficiency Water Heater Models: Consider upgrading to a high-efficiency water heater, such as a tankless or heat pump model. These newer technologies often incorporate advanced temperature control and monitoring features that can enhance Legionella prevention.

Solar Water Heating Systems: Integrating a solar water heating system with your conventional water heater can provide a sustainable, energy-efficient way to maintain the high temperatures needed to control Legionella growth.

Tankless Water Heater Conversions: Replacing a traditional storage tank water heater with a tankless model can reduce the volume of stagnant water, which is less conducive to Legionella proliferation.

Troubleshooting and Repair

Common Water Heater Issues: Be aware of common problems that can impact temperature control and promote Legionella growth, such as sediment buildup, heating element malfunctions, thermostat issues, and pipe scaling or corrosion.

Diagnostic Techniques: Use appropriate diagnostic tools and methods to identify the root cause of any water heater issues that could compromise Legionella prevention, such as temperature probes, water quality test kits, and visual inspections.

DIY Repair Strategies: Perform basic maintenance and repairs, such as flushing the tank, replacing the anode rod, or adjusting the thermostat, to keep your water heater operating at peak efficiency and temperature control.

By following these best practices for water heater maintenance, plumbing techniques, installation, and Legionella prevention, you can safeguard the health and safety of your building’s occupants while ensuring your water heater system operates reliably and efficiently. For more information and water heater solutions, visit waterheaterpick.com.

Tip: Check the anode rod every 2-3 years to prevent corrosion

Heat Pumps & Renewable Energy

We’re the leading providers of renewable energy in the area, but we also offer high-efficiency water heaters and furnaces to help you stay warm, while saving on your monthly bills.

Customer service
Opening hours
Office location

62 Prince Consort Rd, South Kensington, London SW7 2BE

We have a green energy system for everyone!
ECO Certification

MCS Certification: NIC-1111
HIES Member: SUS/A/1111

Official distributor
WATER heater pick logo white

Copyright © 2022 Water Heater Pick