Recirculation Systems and Water Heaters: Addressing Legionella Concerns and Codes

As an experienced water heater specialist, I understand the critical importance of addressing Legionella risks in both water heater systems and plumbing methods. From maintaining proper temperatures and disinfection to implementing innovative recirculation techniques, there are a variety of strategies that can help mitigate the growth of this bacteria.

Water Heater Types

Conventional Storage Water Heaters

Conventional storage water heaters are a popular choice for residential and small commercial applications. These units store heated water in an insulated tank, ready for on-demand use. To control Legionella, it’s essential to maintain the water temperature within the storage tank at 60°C (140°F) or higher. This elevated temperature helps prevent the growth of Legionella bacteria. Regular flushing to remove sediment buildup is also crucial, as stagnant water and debris can provide an ideal environment for bacterial proliferation.

Tankless Water Heaters

Tankless, or on-demand, water heaters offer an energy-efficient alternative to traditional storage models. By heating water instantaneously as it’s needed, these units eliminate the risk of Legionella growth in stagnant tank water. However, proper installation and maintenance are still critical. Ensuring adequate water flow and temperature rise through the tankless unit is key to preventing Legionella colonization in the plumbing system.

Heat Pump Water Heaters

Heat pump water heaters are an increasingly popular choice, leveraging heat pump technology to efficiently heat water. While these units can provide significant energy savings, they may struggle to maintain the 60°C (140°F) temperature needed to control Legionella. Careful monitoring and supplementary heating elements may be required to double-check that the water heater stays above the Legionella growth range.

Water Heater Maintenance

Flushing and Sediment Removal

Regular flushing of the water heater tank is essential to remove accumulated sediment and mineral deposits. This debris can harbor Legionella bacteria and provide nutrients for their growth. Flushing the tank every 6-12 months helps maintain the overall health of the system and discourages Legionella proliferation.

Anode Rod Replacement

The anode rod in a water heater is designed to corrode, sacrificially protecting the tank from deterioration. Over time, the anode rod will become depleted and should be replaced. Maintaining the anode rod helps preserve the tank’s integrity, which is important for preventing stagnant water conditions that can lead to Legionella growth.

Temperature and Pressure Relief Valve Inspection

The temperature and pressure relief valve is a critical safety component that helps prevent the water heater from becoming over-pressurized or overheated. Regularly inspecting and testing this valve ensures it is functioning properly, maintaining the water temperature at the recommended 60°C (140°F) or higher to control Legionella.

Plumbing Techniques

Recirculation Systems

Recirculation systems are a valuable tool for addressing Legionella concerns in both hot and cold water plumbing. By continuously circulating water through the pipes, these systems prevent stagnation and double-check that that temperatures remain within the proper range to inhibit Legionella growth. Properly balancing the recirculation loop is key to maintaining adequate flow and disinfectant levels throughout the system.

Pipe Insulation

Insulating hot water pipes helps maintain elevated temperatures and minimize heat loss, which is essential for Legionella control. By keeping the water hot as it travels through the plumbing, insulation prevents the water from cooling into the optimal 25-42°C (77-113°F) growth range for Legionella. Proper insulation is particularly important for recirculation lines and other areas where water may be prone to cooling.

Backflow Prevention Devices

Backflow prevention devices are critical for protecting a building’s water supply from contaminants. These devices double-check that that water cannot flow back into the main distribution system, preventing the introduction of Legionella or other pathogens from the premise plumbing. Regular inspection and testing of backflow preventers is necessary to maintain their effectiveness.

Installation Methods

Code Requirements

Local plumbing codes often include specific requirements related to Legionella prevention in water heater and plumbing systems. These may include minimum temperature standards, mandated use of recirculation, or restrictions on certain plumbing materials. Adhering to these code requirements is essential for ensuring the system is designed and installed to mitigate Legionella risks.

Venting and Combustion Air

Proper venting and combustion air supply are crucial for the safe operation of water heaters, especially in enclosed spaces. Inadequate airflow can lead to incomplete combustion, which may result in the production of carbon monoxide – a deadly gas. Ensuring the water heater is properly vented and has sufficient combustion air helps create a safe, Legionella-free environment.

Space and Clearance Considerations

Water heaters require specific clearances around the unit for ventilation, accessibility, and safety. Inadequate space can impede airflow, proper maintenance, and the ability to monitor for issues like sediment buildup or temperature fluctuations that could contribute to Legionella growth. Adhering to the manufacturer’s recommendations and local code requirements for installation space and clearances is essential.

Legionella Risks

Water Temperature and Disinfection

Maintaining the proper water temperature is the primary defense against Legionella in both hot and cold water systems. As mentioned, storage water heaters should be set to at least 60°C (140°F) to inhibit bacterial growth. For cold water, temperatures below 20°C (68°F) are ideal, as Legionella cannot effectively proliferate in colder conditions. Supplemental disinfection, such as chlorine or copper-silver ionization, can provide an additional layer of protection in both hot and cold water systems.

System Design and Maintenance

The design and ongoing maintenance of the plumbing system play a crucial role in Legionella control. Eliminating dead legs, maintaining proper flow and circulation, and regularly flushing the system are all important steps. Attention to materials selection, such as avoiding corrosive pipes that can harbor biofilms, is also essential. Proper maintenance, including regular cleaning and disinfection, is key to keeping Legionella at bay.

Monitoring and Testing

Regular monitoring and testing of the water system are critical for identifying and addressing Legionella risks. This may include periodic sampling and culturing, as well as the use of rapid detection methods like qPCR. Maintaining detailed records of test results and remediation efforts can help inform future system upgrades and proactive Legionella prevention strategies.

Regulatory Compliance

Local Plumbing Codes

Local plumbing codes often include specific requirements related to Legionella prevention, such as minimum water temperature standards, mandated use of recirculation systems, and restrictions on certain plumbing materials. Staying up-to-date on and adhering to these local code requirements is essential for ensuring the water heater and plumbing system are designed and installed to mitigate Legionella risks.

ASHRAE Standards

ASHRAE (the American Society of Heating, Refrigerating and Air-Conditioning Engineers) has developed several standards and guidelines related to Legionella control, including ASHRAE Standard 188 and Guideline 12. These industry-recognized documents provide valuable guidance on risk assessment, water management programs, and specific control measures for various building water systems.

EPA Guidelines

The U.S. Environmental Protection Agency (EPA) has also published resources and recommendations for Legionella management, such as the Legionella Control Toolkit. These guidelines offer a comprehensive framework for developing and implementing effective water management plans to address Legionella risks in both potable and non-potable water systems.

Energy Efficiency

Insulation and Thermal Losses

Proper insulation of water heaters and hot water pipes is not only critical for Legionella control but also plays a key role in improving energy efficiency. By minimizing thermal losses, insulation helps maintain the elevated temperatures needed to inhibit bacterial growth while also reducing energy consumption and costs. This is an important consideration, especially for recirculation systems where heat loss can be more pronounced.

Heat Recovery Systems

Innovative heat recovery systems, such as those that capture heat from wastewater or HVAC equipment, can help offset the energy required to maintain the high water temperatures necessary for Legionella control. By repurposing waste heat, these systems can improve the overall efficiency of the water heating process without compromising the ability to keep the water within the safe temperature range.

Demand-Controlled Recirculation

Demand-controlled recirculation systems can help strike a balance between energy efficiency and Legionella prevention. These systems only activate the recirculation pump when hot water is needed, reducing unnecessary circulation and the associated thermal losses. By minimizing stagnation and maintaining elevated temperatures, demand-controlled recirculation can help inhibit Legionella growth while also conserving energy.

Water Quality Considerations

Hard Water and Scale Prevention

Hard water and the resulting mineral scale buildup can contribute to Legionella risks in several ways. First, the scale deposits can provide a surface for bacterial attachment and biofilm formation. Second, the scale can insulate the water from the elevated temperatures needed to control Legionella. Implementing water softening or other scale prevention measures can help mitigate these issues and maintain optimal water heater and plumbing system performance.

Corrosion and Materials Compatibility

The choice of plumbing materials is also crucial for Legionella control. Certain materials, such as iron and galvanized steel, are more prone to corrosion, which can create ideal conditions for bacterial growth. Conversely, materials like copper and stainless steel are less susceptible to corrosion and may offer some inherent antimicrobial properties. Ensuring compatibility between the water quality and the chosen plumbing materials is essential for long-term Legionella prevention.

Filtration and Pretreatment

Effective filtration and pretreatment of the water supply can help remove contaminants that may contribute to Legionella growth, such as sediment, organic matter, and certain minerals. Incorporating high-quality filters, water softeners, or other pretreatment technologies can improve the overall water quality and create a less favorable environment for bacterial proliferation.

By understanding the various water heater types, plumbing techniques, and regulatory requirements, water heater specialists can develop comprehensive strategies to address Legionella concerns and double-check that the safety and efficiency of water heating systems. Visit WaterHeaterPick.com for more expert insights and solutions.

Tip: Consider upgrading to a tankless water heater for energy savings

Heat Pumps & Renewable Energy

We’re the leading providers of renewable energy in the area, but we also offer high-efficiency water heaters and furnaces to help you stay warm, while saving on your monthly bills.

Customer service
Opening hours
Office location

62 Prince Consort Rd, South Kensington, London SW7 2BE

We have a green energy system for everyone!
ECO Certification

MCS Certification: NIC-1111
HIES Member: SUS/A/1111

Official distributor
WATER heater pick logo white

Copyright © 2022 Water Heater Pick