WaterHeaterPickHome & business buying guides

Small heaters for basins and sinks

Moving from a 15 litre to a 30 litre water heater

Why a 30 litre unvented heater is not a drop-in swap for a 15 litre unit, and what to record before an installer assesses the layout.

Work out what is actually running short

Before sizing up, write down what goes wrong. Is it one long task that runs cold, such as filling a sink? Is it several short uses in a row with no time to recover? Or does the heater seem to underperform even on light use, which may point to a fault rather than size?

As a rough ceiling, assume an ideal store at 60°C, cold water at 10°C and mixed water at 40°C. A 15 litre store would give up to about 25 litres of mixed water before recovery, and a 30 litre store about 50 litres. These are upper limits under those assumptions, not product ratings, and real figures will be lower.

Why the larger unit needs its own assessment

Weight changes considerably. Hyco gives the SF15L as 23.4 kg when full [1] and the PF30LS as 45 kg when full [2]. A wall or bracket that suited the smaller unit cannot be assumed to suit the larger one.

Space around the unit also differs. The Powerflow LS manual asks for a minimum of 500 mm below and 200 mm above the heater [2]. Those figures belong to that model and should not be transferred to another product.

An installer will need to check the structure, load and access, the water supply, the plumbing, the safety devices and the discharge arrangement for the exact proposed layout. The electrical supply and connection also need assessing against the exact model, which is a separate check from the hot water safety requirements. Approved Document G covers hot water safety in England, and the installer is the right person to apply it to your installation [3]. Bring your notes on misses and timings so they can judge whether 30 litres solves the real problem.

Sources and scope

  1. Hyco Speedflow instructions v25.9.1

    Full weight of SF15L.

  2. Hyco Powerflow LS instructions v25.9.2

    Full weight of PF30LS and model-specific clearances.

  3. Approved Document G, GOV.UK

    Building Regulations guidance on sanitation and hot water safety.