WaterHeaterPickHome & business buying guides

Small heaters for basins and sinks

Tank litres, usable hot water and V40 explained

Read the capacity figure that answers your task, and keep declared mixed-water output separate from a simple mixing calculation.

Three figures answer different questions

Storage volume describes the water held in the tank. V40 describes a declared quantity of mixed water at 40°C. A calculated mixing estimate describes what your stated temperatures would imply in an ideal model. They are not three names for the same specification.

The Streamline Undersink manual makes the distinction visible in one table: its 7-litre models have a declared V40 of 11 litres, while its 10-litre models have a declared V40 of 15 litres. The table also gives load profile XXS and annual electricity consumption of 595 and 635 kWh respectively. Those annual figures belong to the declaration, not a prediction for your household.[1]

Why a fixed multiplier is misleading

Another manufacturer's table shows why '10 litres means 15 usable litres' is not a rule. STIEBEL ELTRON declares a nominal capacity of 10 litres and mixed water at 40°C of 19 litres for SNU 10 Plus (GB), product number 204981. That is evidence for that appliance's declaration, not proof that it will meet every 19-litre task or outperform another heater under different conditions.[2]

An ideal calculation with 10 litres stored at 60°C, 10°C incoming water and 40°C delivery gives 10 × (60 − 10) ÷ (40 − 10), or about 16.7 litres. This deliberately simplified estimate assumes a fully heated store, ideal mixing and no losses. It neither replaces a declared V40 nor explains every difference between test results. The temperatures are calculation inputs, not settings to apply.

Copy this capacity record into your shortlist

Keep the model identifier and document version beside each number. If the source gives only tank litres, mark usable mixed output unknown rather than inventing a V40. If your task needs a delivery temperature other than 40°C, ask for performance evidence relevant to that task.

  • Exact model and article number; nominal storage volume.
  • Declared V40, with any published test conditions or qualifications.
  • Your task volume, delivery-temperature requirement and repeat interval.
  • Any separate ideal estimate, with inlet and stored temperatures explicitly stated.
  • Recovery and pipe-run allowances still requiring confirmation.

Sources and scope

  1. Heatrae Sadia Streamline Undersink manual, Issue 6

    Page 4 supplies storage volume, V40, XXS load profile and declared annual electricity consumption for the named 7- and 10-litre models. The manual is a bounded example, not evidence of the current label class of every Streamline.

  2. STIEBEL ELTRON SNU Plus (GB) technical datasheet

    Identifies SNU 10 Plus (GB), 204981, with nominal capacity 10 litres and mixed water at 40°C of 19 litres. It does not support substituting that figure for other 10-litre appliances.