Small heaters for basins and sinks
Oversink or undersink: choose the right mounting version
Separate your preferred location from the mounting orientation and exact model that the manufacturer permits.
Above or below is not the same as upside down
Choose where the heater would be least intrusive, but do not infer that moving it above a sink permits turning it over. Hyco's Speedflow v25.9.1 manual allows positioning above or to the side of the outlet provided the appliance remains vertical, with inlet and outlet at the top. It warns that another orientation will cause malfunction.[1]
Other ranges have separate mounting versions. Heatrae Sadia lists distinct Streamline undersink and oversink order codes. For example, its 7-litre 1 kW entries are 95:010:280 for undersink and 95:010:281 for oversink. These are separate identities, not instructions to invert one appliance. Ariston likewise describes over- and undersink models within Andris Lux; the family name alone does not select the version.[2][3]
Compare the location you will actually live with
An undersink position may keep the heater out of sight but compete with the waste trap, bins and stored items. An oversink position may release cupboard space while leaving the case and connections visible. Neither preference establishes an acceptable installation. The installer still needs to assess the permitted position, support, service access and connection arrangements.
Sketch both options without moving existing equipment. Mark the sink, cabinet or wall, door swing, visible pipes and anything that would obstruct later removal. Keep the exact mounting version on each sketch so that a dimension from one version cannot accidentally approve the other.
- Copy the complete model and article number from the proposed version's documentation.
- Record its permitted orientation and connection positions, not just case dimensions.
- Ask whether the proposed location leaves access for normal use, inspection and servicing.
- Ask the installer to confirm support and pipe-routing suitability; do not select fixings or reroute pipes yourself.
If you already own the wrong version
Treat undocumented inversion or horizontal mounting as an unresolved mismatch. Ask the manufacturer or installer about the exact code before deciding whether it can be reused. Similar casings and matching capacities are not evidence of interchangeable internal arrangements.
Sources and scope
- Hyco Speedflow instruction manual v25.9.1
Section 2 requires upright installation with connections at the top, and permits above/to-side positioning while vertical. It is the model-specific basis for the orientation distinction.
- Heatrae Sadia Streamline manufacturer model table
Lists separate undersink and oversink identities, including the exact 7-litre 1 kW order codes quoted. No current availability is inferred.
- Ariston UK: Andris Lux datasheet
Confirms that Andris Lux includes over- and undersink models. This does not establish permission to invert a specific model.