WaterHeaterPickHome & business buying guides

Small heaters for basins and sinks

Will an undersink water heater fit in your cupboard?

Measure the case, obstructions, filled weight and future service space before treating a cabinet as a suitable location.

Measure an installation envelope, not an empty rectangle

A heater can fit between cupboard walls yet be impossible to connect, service or remove. Measure the clear internal height, width and depth with the door closed. Note the door opening separately: hinges, frames and the waste trap can narrow the route into the cupboard. Observe accessible surfaces only; do not disconnect plumbing or move an installed heater.

On a sketch, mark the trap, visible pipes, shelves and anything sharing the space. Ask the installer to add allowances for the proposed connections, accessories, controls and maintenance. Case dimensions alone do not include those needs.

Worked screen: the family name hides a different case

Hyco's Speedflow product page lists SF10K as 410 mm high × 310 mm wide × 280 mm deep. Its v25.9.1 manual lists SF10L as 330 × 330 × 295 mm. Do not borrow the slimmer K-model width when checking an L-model replacement.[1][3]

In an illustrative clear space 360 mm wide and 350 mm deep, the SF10L case leaves only 30 mm across the width and 55 mm across the depth before any other allowance. Those totals are not approved side or rear clearances, and say nothing about height or service access. The correct result is 'case-only screen completed; installation fit unresolved', not 'fits'.

Check the load and the later removal route

The same manual lists SF10L at 6.5 kg empty and 16.5 kg full. The supporting surface has to be assessed for the installed load, not the delivery-box weight; the installer must assess the support and any associated components.[1]

Service allowances are model-specific too. The Streamline Undersink manual specifies 100 mm access above and 50 mm below for maintenance. Those figures belong to that appliance; they are not universal undersink clearances.[2]

  • Record case dimensions and the exact source/model together.
  • Leave accessory space and pipe bends for the installer to confirm.
  • Ask how the label, controls and serviceable parts remain accessible after cabinetry is finished.
  • Show a removal route that does not rely on dismantling permanent kitchen furniture.
  • Ask about leak consequences at the proposed location, not only whether the case will squeeze in.

Sources and scope

  1. Hyco Speedflow instruction manual v25.9.1

    Section 11 supplies SF10L dimensions and empty/full masses; section 2 addresses location and leak consequences. The cabinet example is an arithmetic screen, not an installation clearance specification.

  2. Heatrae Sadia Streamline Undersink manual, Issue 6

    Section 3.2 specifies 100 mm maintenance access above and 50 mm below and requires support for the full appliance weight. These allowances are not transferred to Hyco.

  3. Hyco Speedflow manufacturer product page

    The checked table lists K-coded models, including SF10K dimensions. It is deliberately kept separate from the manual's L-coded specification.