Small heaters for basins and sinks
Small water heater running costs: cycles, standby and annual use
Build an electricity estimate from defined water use and model-specific standing losses, not element wattage alone.
kW describes power; kWh describes energy
A 2 kW element does not necessarily use 2 kWh every hour of the day. It uses energy while operating, and a storage heater cycles to replace heat used or lost. Ofgem distinguishes the electricity unit rate, charged per kWh, from the standing charge paid each day even without consumption.[2]
For one ideal heat-up, energy in kWh is approximately litres × temperature rise in °C × 0.001163. Heating 15 litres through 50°C therefore needs about 0.872 kWh of heat. At an invented example rate of 25p/kWh, that is about 21.8p before losses. This rate is not a current tariff quote. A 2 kW element running continuously for the corresponding ideal 26.2 minutes gives the same energy.
Add standby as a separate, qualified line
STIEBEL ELTRON's SNU 10 Plus (GB) datasheet declares standby consumption of 0.31 kWh per 24 hours at 65°C and 0.11 kWh at 38°C. The temperature condition matters: neither is an unconditional daily allowance for every installation. These are comparison data, not instructions to change settings.[1]
At the same illustrative 25p/kWh, carrying the 0.31 kWh/day declaration across 365 days gives 113.15 kWh, or £28.29. If a source omits the test basis or gives ambiguous loss units, leave the estimate qualified or unknown. Do not substitute another model's figure.
Worked annual worksheet, not a predicted bill
Suppose tasks use 15 mixed litres per weekday, with a 30°C rise from incoming water, on 260 days; there are no weekend draws. Ideal draw energy is 0.523 kWh per use-day, or 136.07 kWh annually. For a deliberately simplified SNU 10 Plus scenario, add the 65°C standby declaration for all 365 days: about 249.22 kWh, or £62.31 at the example rate. This assumes the heater is maintained hot throughout the year; it does not establish that the task fits its delivered performance.
Replace every assumption with your own evidence. Real standby, pipe losses, inlet variation and controls change results. Do not add declared annual label consumption to this calculation: that would mix a separate test schedule with your own. Exclude an existing electricity standing charge from marginal heater savings; show any genuinely new supply charge separately.
- Record weekday, weekend and absence demand separately.
- Keep measured electricity use distinct from theoretical water-heating energy.
- Obtain an appropriate absence plan rather than assuming power-off savings are safe or achievable.
Sources and scope
- STIEBEL ELTRON SNU Plus (GB) technical datasheet
Provides SNU 10 Plus standby consumption at two stated temperatures. Annualisation is a labelled scenario, not a declaration of real household consumption or a settings recommendation.
- Ofgem: Energy price cap and standing charges explained
Explains unit rates per kWh, standing charges independent of use and why bills depend on consumption. No live unit rate or price-cap amount is used.