Small heaters for basins and sinks
Can one small tank serve two nearby outlets?
Separate overlapping draws from successive uses, then check usable water and recovery without treating outlet counts as a guarantee.
Permission to connect is only the first gate
Hyco describes Speedflow as an unvented store that can serve standard taps, with approximate capacity-dependent basin counts. That makes sharing a legitimate question for this family, not proof that any two-tap routine will work. Do not transfer the claim to an open-outlet heater: the Streamline Undersink manual requires its specified vented tap arrangement.[1][2]
Have the installer confirm whether the exact model and proposed outlet arrangement are permitted. Supply pressure, pipe runs, expansion and temperature delivery remain site questions even when the tank appears large enough.
Worked overlapping burst
Suppose two outlets each use 4 litres per minute for two minutes at the same time. Combined demand is 8 litres per minute and 16 litres in total. For a simplified comparison only, a fully heated 10-litre store at 60°C with 10°C incoming water has an ideal mixed-water estimate of 16.7 litres at 40°C. The apparent 0.7-litre remainder is not a useful assurance: the model ignores losses and changing draw temperature. These are arithmetic inputs, not recommended operating temperatures.
A 15-litre store gives 25 ideal mixed litres under those same assumptions, but this still does not verify hydraulic performance or actual usable output. Compare the task with exact declared or tested performance and an allowance for uncertainty, rather than accepting the ideal number as a pass.
Successive users need a time ledger
For staggered uses, list each draw and the gap before the next. A five-minute gap is not automatically a full recovery. At a continuous 2 kW, five minutes supplies about 0.167 kWh: ideally enough heat for roughly 4.8 mixed litres with a 30°C rise. The element may not operate throughout the gap, and actual tank behaviour differs from a uniform energy bucket. Treat this as an upper-limit illustration, not water guaranteed at the tap.
- For each outlet, record task volume, duration, required delivery conditions and start time.
- Flag overlaps and the shortest recovery gaps, not just the daily total.
- Ask what happens when kitchen rinsing coincides with handwashing.
- If the peak sequence remains unsupported, ask about separate supplies or a different capacity/family rather than assuming a bigger basin count solves it.
Sources and scope
- Hyco Speedflow instruction manual v25.9.1
Overview and section 1 establish standard-tap multi-outlet use with capacity/usage qualifications. Burst and five-minute recovery examples are separately calculated ideal scenarios, not tested flow claims.
- Heatrae Sadia Streamline Undersink manual, Issue 6
Section 3 requires the specified open-outlet vented tap arrangement. Used to prevent applying Speedflow's sharing claim across heater families.