Small heaters for basins and sinks
Replacing a small water heater without assuming like-for-like
Build an old-to-new evidence card that keeps model suffixes, mounting, demand and conflicting documents visible.
Identify what is installed before choosing its replacement
Photograph an accessible rating label and transcribe the whole manufacturer name, model, article number, capacity, power and supply rating. Preserve every suffix literally. If a character is unreadable, mark it unreadable; do not turn it into a plausible model code. Do not remove covers or disturb equipment to reach a label.
Add the existing manual and any separate tap or accessory identifiers. A family name such as Speedflow does not establish a single specification. Nor does an old working installation prove that the existing circuit, tap, expansion arrangement or support is suitable for a replacement.
A real example of why documents must stay separate
The checked Hyco product page lists K-coded Speedflow models, while manual v25.9.1 and catalogue v26.1_1 describe L-coded models. The page gives SF10K dimensions as 410 × 310 × 280 mm; the manual gives SF10L as 330 × 330 × 295 mm. These cannot become one combined '10-litre Speedflow' specification.[1][2][3]
The documents differ elsewhere too. The manual and catalogue give different warranty durations for some coverage, and the catalogue lists stainless 3 kW variants not shown in the manual's stainless specification table. Keep the claims attached to their codes and document versions; ask Hyco to resolve the exact proposed article. Do not infer a confirmed successor from a later-looking suffix.[2][3]
Complete the old-to-new comparison
- Family and permitted tap arrangement: open-outlet and unvented are not interchangeable assumptions.
- Storage and documented usable output: compare against today's measured draws and repeat interval.
- Mounting version, connection positions, case envelope and service access.
- Exact element power and supply requirements, for an electrician to assess.
- Full installed weight, supporting surface and installer-specified accessories.
- Document title/version, unresolved conflicts, maintenance obligations and applicable warranty terms.
Can the replacement be smaller?
Possibly, if present-day task demand and recovery windows support it. A smaller household or fewer users is not enough evidence on its own: a single bowl fill can still dominate demand. Compare a measured busiest sequence with the proposed usable output and leave margin for uncertainty. A smaller case or lower element rating does not waive the plumbing, electrical or support checks.
Sources and scope
- Hyco Speedflow manufacturer product page
Checked page retains K-coded model specifications, including SF10K dimensions. It does not prove a particular L-coded model is an approved replacement.
- Hyco Speedflow instruction manual v25.9.1
L-coded dimensions, power/material tables and guarantee section form the replacement evidence baseline; they are not blended with K-coded values.
- Hyco Speedflow catalogue pages v26.1_1
Contains L-coded models and differing warranty/variant statements. Used to expose unresolved document differences, not choose a preferred promise.