50, 80 or 100 litres? Build a peak-demand schedule first

Compare larger direct-electric stores using measured task volumes, useful mixed water and overlapping outlets, rather than bedroom or basin counts.

Define the busiest useful window

A larger store is a reserve of heat, not a promise to supply any number of outlets indefinitely. Start with the busiest 15, 30 or 60 minutes: list each task, required outlet temperature, measured litres, duration and whether another outlet runs at the same time. Include the water drawn while waiting for a distant tap to warm up.

Worked planning example, not a product test: twelve 3-litre washes, two 8-litre sink fills and one 6-litre cleaning draw total 58 litres at the task temperatures you record. Keep those temperatures alongside the volumes; 58 litres required at 55°C is a different duty from 58 litres at 40°C. Repeat the schedule for the next busy window rather than hiding it inside a daily total.

Compare capacity on the same basis

Nominal litres and useful mixed water are different columns. The historical Multipoint SS V manual separately declares 50, 80 and 100 litres of storage and V40 figures of 77, 126 and 157 litres. Those figures belong to those SS vertical models, not to another product carrying the Multipoint name.[1]

For a rough heat-balance illustration only, a fully uniform 50-litre store at 60°C mixed with 10°C cold water would yield about 83 litres at 40°C: 50 × (60 − 10) ÷ (40 − 10). Equivalent ideal results for 80 and 100 litres are about 133 and 167 litres. Real draw-off, stratification, losses and controls mean these are not guaranteed delivered volumes; prefer the exact manufacturer’s declared data.

The SHZ GB sheet illustrates why the model matters: SHZ 50 S (GB), article 232784, declares 50 litres nominal and 80 litres mixed at 40°C; SHZ 100 S (GB), 232786, declares 100 and 133 litres respectively. An 80-litre mixed-water figure is not evidence of an 80-litre tank.[2]

Give the installer two separate questions

First, can the documented reserve and recovery cover the schedule with an agreed margin? Second, can the inlet supply and distribution deliver the simultaneous flows? Passing the thermal-volume check does not answer pressure, pipework or safe installation questions.[1][3]

  • Record outlet distances, concurrent litres/minute and the coldest expected inlet condition.
  • Identify direct electric, indirect cylinder or integrated heat-pump equipment before comparing recovery.
  • Confirm support, discharge route, electrical supply and service space before selecting a capacity.
  • If the needed duty is not documented, keep the outcome at “needs assessment”, not “closest tank wins”.

Sources and scope

  1. [1] Heatrae Sadia Multipoint SS V fitting instructions

    Manufacturer manual 36006070 issue 04, ©2015, retrieved 26 November 2026. Historical SS vertical models only; do not transfer performance to Multipoint Eco.

  2. [2] STIEBEL ELTRON SHZ GB technical datasheet

    Manufacturer datasheet checked in the project evidence on 26 November 2026; exact article numbers, nominal capacity and separately declared mixed water at 40°C.

  3. [3] GOV.UK: Approved Document G for England

    Official publication page retrieved 26 November 2026, linking the edition incorporating 2024 amendments. Hot-water-system safety guidance, not certification of an installation.