WaterHeaterPickHome & business buying guides

One sink, three checks

Plan an under-sink water heater

Compare small 5, 10 and 15 litre under-sink stores by measured draw and cabinet space. Estimate electric running cost and recovery between draws.

Which of 5, 10 or 15 litres should I compare?

Measure how many litres you use for the busiest draw before any recovery. The figures are ideal full-tank ceilings, not usable capacity or V40. Use scenario temperatures; do not change a heater’s settings for this check.

Your draw at the tap
Compare the cabinet bay (optional)

Measure the free rectangular bay after allowing for fixed obstructions. Enter whole millimetres in the stated orientation; do not rotate the case. The door opening and route into the bay are separate checks.

Clear bay
Published Speedflow case sizes

Manufacturer figures in height × width × depth. K codes use the product table; L codes use the L-series instructions. Verify your suffix. No service clearance is included here.

Worked example: 10 L of mixed water at 40°C with a 10°C inlet and 60°C store is above the 8.3 L theoretical ceiling of a 5 L tank. Check a series of draws if the tap is used repeatedly.

What might it cost per full heat and per year?

Use your own electricity rate. Count equivalent full heats, not individual short washes. Or use measured whole-day kWh. Only include standing losses separately in the estimate, never on top of an all-in meter reading.

Heating from cold and heat retention
Your year and unit rate

The ideal full heat assumes water at about 1 kg/L: 4.186 × litres × temperature rise ÷ 3,600 kWh. The yearly estimate applies your schedule on one unit rate and excludes the supplier’s standing charge, installation and maintenance. An off day is modelled as unpowered; any warm-up used on a later use day must be included in that day’s inputs. See the Ofgem explanation of unit rates.

Will the store keep up with the next draw?

Start full and list the draws in order. Enter zero for back-to-back draws. If taps overlap, treat the simultaneous use as one draw for this energy estimate; have peak flow and pressure checked separately.

Do not enter V40 or mixed litres as stored hot water.

Starting store and recovery
Draw 1
Draw 2

Only idle time adds energy, up to the starting capacity. This simplified model assumes constant effective power in each gap until full; it does not model heat loss, thermostat delay, internal mixing, concurrent flows or actual usable delivery.

Sources and scope

  1. Hyco Speedflow product data

    Published K-series body dimensions. Do not copy these figures to an L-series model.

  2. Hyco Speedflow instructions v25.9.1

    Section 11: exact L-series dimensions. Body dimensions do not include installation clearance.

  3. Ofgem: energy price cap and standing charges explained

    Unit rates and household standing charges are different. No current tariff is assumed.