SIZING TOOL · ELECTRIC INSTANTANEOUS
How much heating power do you need?
Enter the total flow through the heater at the target temperature when the outlets run together. Use measured or installer-confirmed figures.
Ideal water-side calculation: 4.186 × L/min × temperature rise ÷ 60. It assumes water is about 1 kg/L. Supply confirmation does not change the heat calculation; it is a prerequisite for checking a particular appliance. The result does not predict delivered flow, prove compatibility or approve an installation.
Compare published model ratings →One basin
Measure the hot path at the basin and check the manufacturer’s minimum flow for activation, not just the power rating. For example, DEM 4 Set (236462) lists 4.4 kW at 230 V and an activation flow above 1.8 L/min. Confirm the specified aerator and tap arrangement before ordering.
Compact single-phase
Know the actual voltage and the load an electrician has allowed for this appliance. Do not treat a retailer’s nominal kW label as the rated power at every voltage; check the code and allowed setting. If the supply is unconfirmed, stop before shopping.
Several outlets on three-phase
Use the simultaneous hot-side flow, not the highest flow at one outlet. The 18/21/24 kW DHB-E set (203866) is one order code with multiple settings at 400 V, not three different products. If demand exceeds the confirmed limit, discuss a cylinder or staggered use.