WaterHeaterPickHome & business buying guides

Electric instantaneous heaters

Switch-on flow thresholds: why near enough is not a pass

Reading the DEM Set switch-on flows correctly, treating uncertain estimates honestly, and keeping activation separate from useful delivery.

What the datasheet states

The Stiebel Eltron DEM Set technical datasheet lists a switch-on water flow rate for each model. Each figure has a strict greater-than sign. A flow equal to the figure does not meet it.

  • DEM 3 Set: switch-on flow above 1.5 l/min.
  • DEM 4 Set: switch-on flow above 1.8 l/min.
  • DEM 6 Set: switch-on flow above 2.2 l/min.

Worked check with an uncertain estimate

Suppose your best estimate of the flow through the heater is 1.6 l/min, give or take 0.2. The real value could be anywhere from 1.4 to 1.8 l/min.

For the DEM 3 Set, that range crosses the 1.5 threshold. The result is inconclusive, not a pass. For the DEM 4 Set, no part of the range is above 1.8, so the estimate does not show the threshold being exceeded. The DEM 6 Set threshold of more than 2.2 is outside the range altogether. Write down the range rather than the middle figure.

Activation is not delivery

A switch-on threshold only says when the heater starts. It does not mean the water will reach a useful target temperature, or that the supply will stay steady. Those depend on rated output, temperature rise and flow. The switch-on threshold and the rated delivery are different figures, so do not swap one for the other.

The figure that matters is the flow through the heater, not the total flow from a tap that mixes hot and cold. The DEM product page describes variable flow-rate limitation and an integral flow controller, so the tap flow may not match what the appliance sees.

What to do instead of forcing it

Do not adjust aerators, flow controllers, taps or valves to make the heater switch on. Collect observations from normal use and give them to the installer. If you notice a leak, unexpected heat, a burning smell, damage or any electrical symptom, stop and keep away. Contact the landlord or a qualified professional, or call the emergency services if there is immediate danger.

  • Exact model and part number, for example 236584, 236462 or 236463.
  • Where the flow figure came from, and its uncertainty.
  • Whether it was heater-side flow or total tap flow.
  • Normal observations of when heating seemed to start.
  • A question for the installer: what heater-side flow did commissioning establish?

Sources and scope

  1. Stiebel Eltron DEM 3 Set technical datasheet

    Switch-on flows above 1.5, 1.8 and 2.2 l/min, part numbers and rated outputs, kept separate.

  2. Stiebel Eltron DEM 3 Set product page

    Variable flow-rate limitation, integral flow controller and one-washbasin application.