WaterHeaterPickHome & business buying guides

Electric instantaneous heaters

Paired power ratings: one article number, several declared outputs

Why the same product can show different kW figures at different voltages, and how to record and compare those figures fairly.

Same product, different rows

Datasheets often list outputs at several rated voltages for a single article number. These are not different products. The Stiebel Eltron DEM 4 Set, article 236462, is declared at 4.4 kW at 230 V and 4.8 kW at 240 V.

The DCE-S 6/8 Plus, article 238153, also has two output selections, and each one changes with voltage.

  • DCE-S 6/8 Plus at 220 V: 6.0 or 8.0 kW.
  • At 230 V: 6.6 or 8.7 kW.
  • At 240 V: 7.2 or 9.6 kW.

The model title is not the power basis

The name 6/8 matches the 220 V row. It does not tell you the output at your voltage, and it does not tell you which selection was made at installation. Use only the rows the maker has declared. Do not extrapolate to other voltages with a general formula, and do not carry out any electrical test or supply change to find out.

Record before you compare

Record what the documents say. The output selection should have been recorded by the installer; if no record exists, treat the selection as unknown and hold the comparison. Do not open or access the equipment to find out, and you do not need to ask anyone to change it.

  • Exact model code and article number.
  • Datasheet or manual revision and the date you checked it.
  • The declared rated voltage for the site, taken from existing professional records.
  • The output selection, as shown in the installer's or commissioning record.
  • Anything that is unknown, marked as unknown.

Worked comparison

Imagine one note says the DEM 4 Set gives 4.8 kW and another says the DCE-S 6/8 Plus gives 6.0 kW. The first figure is the 240 V row. The second is the 220 V row at the lower selection. Comparing them as they stand mixes up two different bases.

Line them up first. At 230 V, the figures are 4.4 kW and either 6.6 or 8.7 kW, depending on the recorded selection. Only after that should you compare thermal conditions such as inlet temperature, required rise and flow. If the voltage or selection is unknown, the comparison is on hold until the installer or maker confirms it.

If you notice a leak, unexpected heat, a burning smell, damage or any electrical symptom, stop and keep away. Contact the landlord or a qualified professional, or call the emergency services if there is immediate danger.

Sources and scope

  1. Stiebel Eltron DEM 3 Set technical datasheet (covers DEM 4 Set)

    DEM 4 Set, part 236462: 4.4 kW at 230 V and 4.8 kW at 240 V.

  2. Stiebel Eltron DCE-S 6/8 Plus technical datasheet

    Part 238153: 6.0/8.0 kW at 220 V, 6.6/8.7 kW at 230 V and 7.2/9.6 kW at 240 V.