Electric instantaneous heaters
Overlapping basin use versus tasks one after another
Why two basins running at once is a different question from total daily use, and why passing arithmetic cannot widen a documented application.
Overlap is not the same as daily volume
Ten hand washes spread across a morning ask very little of the heater at any one moment. Two basins running at the same time ask for both flows at once. An instantaneous heater has to meet the flow at that moment, so overlapping use is a separate question from how much water is used in a day.
The documented application sets the limit
The Hyco Ara manual says its heater is for light hand washing at a single basin only. The DEM Set product page says it can supply one washbasin. If a calculation seems to allow more, that does not extend what the maker has stated.
The DCE-S 6/8 Plus is described as supplying either several hand washbasins or a shower. That wording does not guarantee any particular amount of overlapping use.
Worked example (hypothetical, not a model rating)
Take a hypothetical 6 kW heater, a 10°C inlet and a 40°C target, which is a 30 K rise. One basin wants 2 l/min. Two basins at once want 2 + 2 = 4 l/min.
Stiebel Eltron's rounded thermal rule estimates the outlet temperature as 14 × kW ÷ flow, plus the inlet temperature. At a 30 K rise, the most flow this allows is 14 × 6 ÷ 30 = 2.8 l/min. At 4 l/min, the rise is only 14 × 6 ÷ 4 = 21 K, which gives about 31°C before any losses. So the overlap cannot be met at both 4 l/min and 40°C at once: at that flow the theoretical outlet is about 31°C. This is a temperature shortfall, not a sign that the flow itself has failed. One basin on its own falls within the theoretical limit, but that is still not a rating for any actual product.
- Theoretical maximum at a 30 K rise: 2.8 l/min.
- At 4 l/min: 21 K rise, about 31°C, before losses.
- Result: this overlap does not work, even on paper.
What to record and who checks the rest
Write down how use actually happens. Do not run several outlets on purpose to stress-test the system. How the water pressure behaves under load needs to be checked by the installer. Pipework design is not something to work out yourself.
If you notice a leak, unexpected heat, a burning smell, damage or any electrical symptom, stop and keep away. Contact the landlord or a qualified professional, or call the emergency services if there is immediate danger.
- Which outlets overlap, and for how long.
- How many users, and at what times of day.
- The exact model and its stated application.
Sources and scope
- Hyco Ara IN30TN instruction manual v26.1.1
Light hand washing at a single basin only.
- Stiebel Eltron DEM 3 Set product page
Can supply hot water to one washbasin.
- Stiebel Eltron DCE-S 6/8 Plus product page
Supplies either several hand washbasins or a shower.
- Stiebel Eltron DHW basic principles guide
Rounded thermal rule using 14 × kW ÷ flow, which excludes losses and margins.