Electric instantaneous heaters

Control behaviour: what the display and the delay actually mean

How fixed-output heaters, target-temperature heaters and closed-loop heaters behave differently, and how to record what you see without changing anything.

Examples of documented control behaviour

The Hyco Rho IN44 and IN60 have no external controls. They operate when a flow greater than 2.5 l/min passes through. Because the maximum power is fixed, the temperature rise changes with flow: higher flow means a lower rise.

The Hyco Ara IN30TN has an electronic target temperature. The manual states that the unit aims for the target and will never exceed it. This is the maker's description of how the control behaves, not a safety or anti-scald guarantee, and it is no reason to ignore unexpectedly hot water, which remains a sign to stop using the heater and keep away. The manual also states that if the target is outside what the unit can achieve, it gets as close as it can. Its display shows the current water temperature, and only while water is flowing.

The Stiebel Eltron DEM Set uses electronic closed-loop control. It claims accurate temperature delivery up to the maximum output. Beyond that limit, the power available still decides the result.

More controls do not mean more power

A display or a target setting changes how the available power is managed. It does not add any power. A heater with controls can still fall short when the flow or the required rise is too high.

The Ara start-up delay

The Ara manual reports a delay of about 12 seconds of continuous flow before heating starts, both on first installation and after a power interruption. This is background information documented for that model only. It is not an instruction to restart, reset, switch the power off and on, or force flow, and it is not a benchmark for other heaters.

If you already have normal timings from everyday use, they can help frame a question for the service department. They do not diagnose a fault.

Recording checklist

Record the settings and display as you find them. Do not change settings to see what happens.

  • Exact model code and manual revision.
  • Control behaviour, in the manual's own wording (for example: no external controls; electronic target temperature; electronic closed-loop control). These descriptions can overlap, so quote the maker rather than choosing a category.
  • What the display means for this model: setpoint or current temperature.
  • Setpoint as found, compared with the actual reading shown, where the model displays both.
  • Flow figure and its source.
  • Inlet stand-in temperature, and the date and time.
  • Any recent power interruption that you know of.
  • The behaviour the manual describes for this situation.

Safety

If you notice a leak, unexpected heat, a burning smell, damage, any electrical symptom or possible freezing, stop and keep away. Contact the landlord or a qualified professional, or call the emergency services if there is immediate danger.

Sources and scope

  1. Hyco Rho IN44/IN60 instruction manual v23.10.6

    No external controls, operation above 2.5 l/min, and fixed maximum power with lower uplift at higher flow.

  2. Hyco Ara IN30TN instruction manual v26.1.1

    Target never exceeded, closest achievable result outside the performance range, display during flow, and the roughly 12-second start delay.

  3. Stiebel Eltron DEM 3 Set product page

    Closed-loop control with accurate temperature delivery up to the maximum output.