WaterHeaterPickHome & business buying guides

Electric instantaneous heaters

Supply limits: pressure, flow, inlet temperature and water resistivity

Treating each maker's supply limits as separate conditions for that model, handling contradictions honestly, and preparing a useful handoff for the installer or maker.

Separate limits, one model at a time

The Hyco Rho IN44/IN60 specification lists several separate limits. Working pressure is 0.1 to 0.75 MPa, which is 1 to 7.5 bar. The minimum flow is 2.5 l/min, and the heater operates when flow greater than 2.5 l/min is detected. Maximum inlet temperature is 48°C, and water resistivity must be at least 1300 Ωcm. The manual permits pre-heated water up to 48°C for this model only.

The Hyco Ara IN30TN gives a maximum inlet temperature of 30°C. The Rho permission therefore does not carry over to the Ara or to any other model.

Resistivity is its own question

Resistivity is not the same thing as water hardness or water pressure. Makers also state it under particular reference conditions. The Ara states it at 15°C, and the DEM Set datasheet gives different limits depending on cold-water temperature. Ask the maker or installer what dated supply evidence applies and which reference conditions it needs to meet. Do not use probes yourself, add water treatment, or assume a conversion from some other figure.

What a jug cannot prove

A timed cold-water jug shows a volume over a time. It cannot prove pressure under load, and it cannot show resistivity.

Contradictions are held, not resolved

The Ara specification gives a minimum operating pressure of 0.1 MPa, which is 1 bar. Its troubleshooting table says to ensure a minimum of 0.05 MPa, which is 0.5 bar. Report this inconsistency to the maker and ask which figure applies. Do not choose the less restrictive value.

  • A known value outside a limit: no verified match.
  • An unknown value or a conflict between documents: hold, not pass.
  • Every limit documented and met: still not approval to install.

Handoff checklist

Gather this in one place for the installer or maker. Meeting the listed limits is not installation approval, and only a qualified person can decide suitability.

  • Exact model codes and the manual revision.
  • Every stated limit, with its unit and reference condition.
  • Site evidence you hold, with dates and sources.
  • Unknowns and contradictions, listed openly.
  • Who will verify each item.

Safety

If you notice a leak, unexpected heat, a burning smell, damage, any electrical symptom or possible freezing, stop and keep away. Contact the landlord or a qualified professional, or call the emergency services if there is immediate danger.

Sources and scope

  1. Hyco Rho IN44/IN60 instruction manual v23.10.6

    Pressure of 1 to 7.5 bar, minimum flow of 2.5 l/min with operation above it, 48°C maximum inlet and pre-heat permission, and resistivity of at least 1300 Ωcm.

  2. Hyco Ara IN30TN instruction manual v26.1.1

    30°C maximum inlet, resistivity at 15°C, and the 1 bar specification against the 0.05 MPa troubleshooting figure.

  3. Stiebel Eltron DEM 3 Set technical datasheet

    Resistivity and conductivity limits that depend on cold-water temperature, showing that reference conditions matter.

  4. Yorkshire Water: water pressure

    Timed-jug method measures flow only, as volume over time.