Electric instantaneous heaters

Auditing flow claims: making two figures comparable

A fair-comparison checklist for flow claims, a worked example of normalising to the same rise, and why identifier mismatches should be reported rather than quietly fixed.

Audit fields for every claim

A flow figure means nothing on its own. Record each of these before you compare.

  • Exact model code and article number.
  • Voltage and output selection.
  • Inlet temperature and outlet temperature.
  • Temperature rise, written as ΔT.
  • Whether the figure is heater flow or total mixed flow.
  • The maker's chart or source, with its revision.

Worked example: the bigger headline is not better

Hypothetical claim A says 4 l/min at a 25 K rise. Claim B says 3 l/min at a 35 K rise. A looks bigger, but B is heating water through a larger rise.

To compare them at the same 30 K rise, scale each flow in proportion. For A, 4 × 25 ÷ 30 ≈ 3.33 l/min. For B, 3 × 35 ÷ 30 = 3.5 l/min. This assumes the usable heating power stays the same and that nothing is actively restricting flow. It is a mathematical normalisation, not a checked product rating, and it does not pick a winner.

When a figure cannot be compared

If a claim states both an inlet and an outlet temperature, ΔT is the outlet minus the inlet. If a claim gives no ΔT and no stated inlet and outlet pair from which to derive it, it cannot be compared. Do not fill in an assumed inlet temperature to make it fit. Ask the maker for the conditions. Published curves and tables for the exact model, under stated conditions, always outrank your own arithmetic.

Keep identifier mismatches visible

The Hyco Rho manual covers models listed as IN44 and IN60 in its overview and specification. Its temperature performance table is headed IN44T and IN60T. Record that difference exactly as printed. Ask the maker to confirm that the table applies to your model code. Do not quietly treat the labels as the same.

That table gives, for example, a maximum rise of 34°C at 2.5 l/min for the column labelled IN60T. Quote it with its label. A maximum figure from a table is not a guarantee of what any installation will deliver.

Safety

If you notice a leak, unexpected heat, a burning smell, damage or any electrical symptom, stop and keep away. Contact the landlord or a qualified professional, or call the emergency services if there is immediate danger.

Sources and scope

  1. Hyco Rho IN44/IN60 instruction manual v23.10.6

    IN44/IN60 overview and specification, and a performance table labelled IN44T/IN60T with maximum rise by flow.

  2. Stiebel Eltron DHW basic principles guide

    Power, flow and rise relationship, given as a rounded theoretical rule that excludes losses.

  3. Stiebel Eltron DCE-S 6/8 Plus technical datasheet

    Shows declared output varying with voltage and selection, which is why those fields must be audited.