Electric instantaneous heaters
Winter flow and temperature rise: reading the numbers without guessing
How the incoming water temperature changes what a fixed-power instantaneous heater can deliver, how to keep a safe cold-water record, and how to look at a winter complaint without changing anything.
Start with the rise, not the outlet figure
Any instantaneous heater has a fixed maximum power, so the useful number is the temperature rise: the outlet temperature you want minus the temperature of the water coming in. At the same power, a higher required rise means a lower possible flow. Put the other way, if the flow stays the same, a colder inlet gives a cooler outlet.
The Hyco Ara IN30TN manual shows this clearly. With its supplied 1.6 l/min restrictor it states an uplift of 27°C. Its example is a 15°C inlet giving 42°C. In a hypothetical case with an 8°C inlet, the same 27°C uplift at the same flow would give about 35°C. The manual itself warns that winter inlet temperatures may fall below 10°C, and it gives 37°C at a 10°C inlet.
These are labelled scenarios, not national winter constants. The Rho manual, for example, uses 13°C as its winter example. None of these outlet figures is a guaranteed or safe target temperature.
- Required rise = wanted outlet temperature minus inlet temperature.
- Ara example: 15°C inlet + 27°C = 42°C. Hypothetical: 8°C inlet + 27°C = 35°C, at the same 1.6 l/min.
- A larger required rise at the same power means less flow, not more.
Keeping a safe cold-water record
If you want a local inlet figure, use only cold water. Fill a container from an accessible cold tap and use an external thermometer meant for cold liquids, following that instrument's own instructions. A reading from a cold tap is only a stand-in for the heater inlet until a qualified person confirms that the tap and the heater share the same feed. Never open the heater, its cover or any pipework to get a better reading.
One reading is not a seasonal design case. Repeat the same safe observation on different days and at different times.
- Date, time and which tap you used.
- How long you let the reading settle, as the instrument instructions describe.
- The thermometer's resolution, for example whole degrees, and its stated accuracy if the instrument gives one.
- The spread between repeat readings taken in the same way. Even with these details, a cold-tap reading remains a stand-in only.
- Anything else using water at the same time.
Winter triage without touching settings
If the hot water seems weaker in winter, compare records you already have. Look at the flow, the inlet stand-in, the controls exactly as you found them, the time of day, any start-up delay and the exact model code. Do not change any settings to test an idea. A sudden or unexplained change cannot be put down to winter, and nor can any safety symptom.
When to stop
The Ara manual says not to use the appliance if there is any possibility that the water supply is frozen. In that case, or if you notice any of the signs below, stop using the heater, stop making observations and keep away. Contact the landlord or a qualified professional. If there is immediate danger, call the emergency services.
- A leak or water where it should not be.
- Unexpected heat or a burning smell.
- Visible damage or any electrical symptom.
- Possible freezing of the heater or its pipes.
Sources and scope
- Hyco Ara IN30TN instruction manual v26.1.1
1.6 l/min with 27°C uplift; 15°C to 42°C and 10°C to 37°C examples; winter inlet warning; instruction not to use if the supply may be frozen.
- Hyco Rho IN44/IN60 instruction manual v23.10.6
Higher flow gives lower uplift at fixed power; a different maker example uses 13°C as its winter figure.
- Stiebel Eltron DHW basic principles guide
Thermal relationship between power, flow and temperature rise, given as a rounded theoretical rule.