WaterHeaterPickHome & business buying guides

Hot water for businesses

A handwash heater is not automatically a salon hairwash heater

Build a hairwashing duty brief around sustained flow and repeat appointments, and reject products whose manufacturer excludes the application.

An explicit exclusion ends the shortlist

Hyco’s glass-lined Speedflow page explicitly says it is not suitable for hairwash basins in hairdressing salons. The same page’s approximate one-to-three-basin guide concerns its stated light handwashing and kitchen duties; it does not override that exclusion. A larger member of the same excluded range is not a supported salon recommendation.[1]

Use this rule before comparing litres or price: confirm that the manufacturer documents the exact product for the actual task. A comfortable first rinse does not demonstrate temperature stability through the appointment or recovery before the next customer.

Worked duty screen, not a heater recommendation

Assume two backwash stations each need 4 litres/minute for eight overlapping minutes, with 40°C delivery and 10°C inlet. The combined draw is 64 litres. The ideal useful heat for that water is approximately 2.23 kWh, or about 16.7 kW of instantaneous thermal output during the overlap. These are illustrative assumptions, not prescribed salon flow or temperature settings.

A storage system might meet a burst using a previously heated reserve, but it still needs documented useful volume and replenishment for the next bookings. An instantaneous alternative needs evidence for actual winter inlet, activation, temperature control and the site’s assessed electrical supply. The calculation alone selects neither family and does not make an excluded product suitable.

Ask the supplier and installer these questions

Record separate handbasin and hairwash duties even if they might share a proposed system. Keep colour-processing, cleaning and any other specialist requirements explicit rather than folding them into “two basins”.

  • What is the measured flow and duration at each hairwash station, including longer rinse tasks?
  • Which appointments overlap, and what recovery opportunity remains between them?
  • Does the manufacturer confirm the exact model and control arrangement for salon hairwashing?
  • What delivery-temperature stability and mixing evidence applies at the measured inlet pressure and temperature?
  • Who checks simultaneous flow, supply capacity, distribution, safe temperature control and maintenance access?
  • If application evidence is missing or exclusion is explicit, stop the shortlist and request a supported system design—not a higher basin count.

Sources and scope

  1. [1] Hyco Speedflow manufacturer specification

    Retrieved 26 November 2026; light dishwashing/handwashing application, explicit salon hairwash exclusion, 1.2/2.0 kW variants and the 70%-capacity theoretical heat-up footnote.