Electric instantaneous heaters
4.4 kW or 6 kW instantaneous handwash heater: Hyco Rho IN44 vs IN60
A like-for-like look at the non-thermostatic Hyco Rho IN44 and IN60. It covers rated figures, the documented activation flow, and why ideal arithmetic is not an operating point.
What the two exact models share
The Hyco Rho IN44 and IN60 are non-thermostatic instantaneous inline heaters intended for handwashing at a single basin [1]. The manual says both are for spray-head taps with removable M22/M24 nozzles. It also says they are not suitable for thermostatic mixing valves or taps, or for supplying a single-lever mixer tap [1].
Neither model has external controls. Each simply operates when it detects enough flow passing through it [1]. This guide covers these two non-T codes only. Controls or features from thermostatic models do not carry over to them.
Rated figures in the specification
The specification table in manual v23.10.6 lists the following [1]. These are rated currents for each appliance. They are not fuse ratings, and they say nothing about the cable, protection or supply in a particular home. Only an electrician can confirm whether a property can support either model.
Section 4 says the heater operates when flow greater than 2.5 L/min is detected passing through the appliance. The specification lists a minimum operating flow of 2.5 L/min [1]. Read together, they show that a flow of exactly 2.5 L/min is not demonstrated to activate either heater. The documented condition is flow above that figure.
Why a nominal power comparison is not an operating point
An ideal, lossless estimate of flow is: flow (L/min) = kW × 60 ÷ (4.186 × temperature rise). Take an example with a 10°C inlet and a 40°C target, which is a 30°C rise. The formula gives about 2.10 L/min for the IN44 and about 2.87 L/min for the IN60, using the rated powers [1]. These are worked examples, not appliance output.
The IN44 figure of 2.10 L/min is below that model's documented activation condition of more than 2.5 L/min [1]. So the example does not describe a flow at which the IN44 would run. Reducing flow to chase that target is not a route this guide recommends.
The IN60 figure sits above the threshold, but it remains theoretical. Neither the delivered temperature nor the suitability of the supply has been established. The manual also notes that higher flow means lower potential temperature rise [1]. Its temperature table is labelled IN44T/IN60T, so those figures are not used here for the non-T codes.
What to take to an installer
Keep the conversation practical and specific to the exact appliance.
- The exact model code, IN44 or IN60, not a T variant
- Any cold inlet temperature already recorded by a professional
- The expected flow through the heater itself, separate from any cold water blended at the tap
- The intended spray-head tap and its nozzle
- Supply details confirmed by an electrician
Sources and scope
- Hyco Rho IN44, IN60 instruction manual v23.10.6
Intended use, operation at flow greater than 2.5 L/min, and the specification table with rated power, voltage and rated current.